Fire Pipe-UL 852 Fire Production Pipe
TUSPIPE’s fire protection piping is UL 852 certified. We also offer galvanized and FBE-coated Kanto piping. This ensures your fire protection piping can withstand high temperatures and pressures while maintaining safe and stable operation.
UL 852 Fire Pipe
UL 852 fire pipe is a type of pipe that is specifically designed for fire fighting applications. The pipe is made from materials that are resistant to high temperatures and pressure, making it ideal for use in fire suppression systems. The pipe is also fitted with special fittings that allow it to be quickly connected to fire hoses and other fire fighting equipment.
In addition, the pipe is regularly inspected and tested by UL, an independent safety organization, to ensure that it meets the highest standards for safety and performance. As a result, UL 852 pipe for fire fighting is the preferred choice for many commercial and industrial buildings.
fire Pipe Technical Parameters
그리고 UL 852 pipe is a type of fire pipe that is commonly used in fire fighting systems. It is also known as a standpipe. The fire sprinkler pipe is used to connect the fire fighting equipment to the water supply. Many different types of coatings are available for the fire sprinkler pipe.
The most common type of coating is galvanizing. The galvanizing will protect the fire pipe from corrosion. The other type of coating that is available is FBE. The FBE coating will protect the pipe from UV rays and will also provide a barrier against chemicals.
The other type of coating that is available is varnish coatings. The varnish coatings will provide a barrier against water and will also provide a barrier against corrosion. The color of the fire sprinkler pipe is usually red or orange. The zinc silver color is also available. The coating thickness for the fire sprinkler pipe is 250 microns to 550 microns. The working temperature for the fire sprinkler pipe is -30 degrees Celsius to 80 degrees Celsius (-22 degrees Fahrenheit to 176 degrees Fahrenheit). The working pressure for the fire sprinkler pipe is 0.1 megapascals to 0.25 megapascals.
Welding joints are strong and secure, but they require special equipment and training to create. Threaded connections are easy to create and can be disassembled if necessary, but they are not as strong as welding joints. Grooved connections are similar to threaded connections, but they provide a better seal against leaks. Flanged connections are the strongest type of connection, but they are also the most difficult to create. Ultimately, the best connection for a given application will depend on the requirements of the job.
Dimensions and Sizes of fire Pipe for Fire Fighting
| N.D. | O.D. | SCH 10 | SCH 30/40 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| WALL THICKNESS | NOMINAL WEIGHT | WALL THICKNESS | NOMINAL WEIGHT | ||||||||
| (mm) | (Inch) | (mm) | (Inch) | (mm) | (Inch) | (kg/mtrs) | (lbs/ft) | (mm) | (Inch) | (kg/mtrs) | (lbs/ft) |
| 15 | 1/2 | 21.3 | 0.84 | —- | —- | —- | —- | 2.77 | 0.109 | 1.27 | 0.85 |
| 20 | 3/4 | 26.7 | 1.05 | 2.11 | 0.083 | 1.28 | 0.96 | 2.87 | 0.113 | 1.69 | 1.13 |
| 25 | 1 | 33.4 | 1.32 | 2.77 | 0.109 | 2.09 | 1.41 | 3.38 | 0.133 | 2.5 | 1.68 |
| 32 | 1-1/4 | 42.2 | 1.66 | 2.77 | 0.109 | 2.69 | 1.81 | 3.56 | 0.14 | 3.39 | 2.27 |
| 40 | 1-1/2 | 48.3 | 1.9 | 2.77 | 0.109 | 3.11 | 2.09 | 3.68 | 0.145 | 4.05 | 2.72 |
| 50 | 2 | 60.3 | 2.38 | 2.77 | 0.109 | 3.93 | 2.64 | 3.91 | 0.154 | 5.45 | 3.66 |
| 65 | 2-1/2 | 73 | 2.88 | 3.05 | 0.12 | 5.26 | 3.53 | 5.16 | 0.203 | 8.64 | 5.8 |
| 80 | 3 | 88.9 | 3.5 | 3.05 | 0.12 | 6.46 | 4.34 | 5.49 | 0.216 | 11.29 | 7.58 |
| 90 | 3-1/2 | 101.6 | 4 | 3.05 | 0.12 | 7.41 | 4.98 | 5.74 | 0.226 | 13.58 | 9.12 |
| 100 | 4 | 114.3 | 4.5 | 3.05 | 0.12 | 8.37 | 5.62 | 6.02 | 0.237 | 16.09 | 10.8 |
| 125 | 5 | 141.3 | 5.56 | 3.4 | 0.134 | 11.58 | 7.78 | 6.55 | 0.258 | 21.79 | 14.63 |
| 150 | 6 | 168.3 | 6.63 | 3.4 | 0.134 | 13.85 | 9.3 | 7.11 | 0.28 | 28.29 | 18.99 |
| 200 | 8 | 219.1 | 8.63 | 4.78 | 0.188 | 25.26 | 16.96 | 7.04 | 0.277 | 36.82 | 24.72 |
| 250 | 10 | 273.1 | 10.75 | 4.78 | 0.188 | 31.62 | 21.23 | 7.08 | 0.307 | 51.05 | 34.27 |
Manufacturing Procedures of fire pipe-UL 852 fire pipe
Generally, ERW is the most common method of manufacturing UL-listed fire pipes for fire fighting.
This technology was developed in the 1930s and was used extensively in coil-to-coil welding. As coil ends were welded, lap coils were formed that needed to be trimmed before further processing could continue.
Today, advances in high-frequency current welding have made it possible to produce ERW pipe that does not require coil-to-coil welding. This process begins with a flat coil of steel being unwound and passed through consecutive sets of rollers that progressively shape it into a tubular product. As the coil emerges from each set of rollers, it passes through an electrode that uses a high-frequency current to weld the edges together, thereby creating a welded pipe product. Afterward, various heat treatments may be applied to achieve desired strength characteristics for the finished product. The high quality and versatility of ERW pipe make it ideal for a variety of applications, including fire fighting, oil and gas transmission, structural tubing, and construction.
Different Connection Types of UL 852 Pipes
There are several types of connections used in UL 852 fire sprinkler piping system. The most common are welding joints, threaded connections, grooved connections, and flanged connections. Each type has its own advantages and disadvantages, so it is important to choose the right one for the job at hand.
Welding joints are strong and secure, but they require special equipment and training to create. Threaded connections are easy to create and can be disassembled if necessary, but they are not as strong as welding joints. Grooved connections are similar to threaded connections, but they provide a better seal against leaks. Flanged connections are the strongest type of connection, but they are also the most difficult to create. Ultimately, the best connection for a given application will depend on the requirements of the job.
Test and Inspection on UL 852 fire production Pipe
To ensure that our UL 852 pipe for fire fighting meets the highest standards of quality and safety, we subject it to a rigorous series of tests during production.
First, we perform a chemical analysis to check the composition of the material.
Then, we conduct a tensile test to measure the strength of the fire pipes under tension.
Next, we bend the pipes to see how well they retain their shape.
Finally, we flatten the pipes to check for any weak spots or flaws.
We also hydrostatic test the fire pipes by filling them with water and checking for leaks.
Finally, we use weld seam ultrasonic or electromagnetic testing to ensure that the welds are strong and free from defects.
By subjecting our fire sprinkler pipe to these tests, we can be confident that it meets the highest standards of quality and safety.
What is UL?
UL (Underwriters Laboratories) is a global safety certification company that tests products and writes standards for product safety. The UL mark is proof that a product has been tested by UL and meets the safety requirements in UL’s Standards for Safety.
Products that have the UL mark have undergone rigorous testing and are regularly inspected to ensure they continue to meet UL’s safety standards. UL 852 products are some of the safest products on the market and are trusted by consumers and businesses worldwide.
Marks on UL 852 Pipe for Fire Fighting
그리고 UL 852 fire pipe body is marked with the following information: name of manufacturer, pressure, heat number, steel grade, and the UL 852 certification mark. The nominal pipe sizes and length are also included in the fire pipe body. The schedule or model reference may be included on the fire pipe body as well. This information is important to ensure that the fire pipe is installed properly and is up to code. The UL 852 certification mark ensures that the fire pipe has been tested and meets all safety standards.
왜 투스피프를 선택해야 하나요?
1998년부터 Tianjin United Steel Piping Co., Ltd(TUSPIPE)는 고품질의 라인 파이프를 공급하기 위해 노력해 왔습니다.
연간 50만 톤 이상의 생산 능력을 갖춘 이 회사는 석유 및 가스 개발 및 송전, 선박 및 자동차 건조, 수도 및 전기, 환경 보호, 기계 공학, 인프라 건설 등 다양한 분야와 산업에 서비스를 제공하고 있습니다.
TUSPIPE는 제품 품질과 엄격한 제품 품질 관리를 중요하게 생각합니다. 우수한 제품 품질을 유지하기 위해 2004년부터 테스트 및 검사 센터를 설립했습니다. 일련의 최첨단 테스트 및 검사 장비를 갖춘 테스트 & 검사 센터는 인장 테스트, 수압 테스트, 충격 테스트, DWTT 등을 수행할 수 있습니다.